PHPK purchased the CVI Torr Master cryopump and cryocooler product line from Chart Industries.
The coldhead refrigeration is based on the Gifford-McMahon expansion engine design.
| TorrMaster | TM 900 | TM 1200 |
|---|---|---|
| N2 | 30,000 l/s | 57,000 l/s |
| H2 | 20,000 l/s | 30,000 l/s |
| Flange | 35 in ANSI | 48 in ANSI |
First stage array is cooled to a nominal 77 K, freezing out water vapor and providing thermal radiation shielding for the second stage. The inner or second stage array is cooled to a nominal 15-20 K for rapid pumping of nitrogen and oxygen. Helium, hydrogen and neon are pumped by absorption on a bed of activated carbon cooled to 15-20 K by the inner array. Torr Masters have no moving parts or operating fluids exposed to the vacuum.