Rebuilt Stokes Stealth Pump
 | | Model | cfm | hp | kW | Rebuilt |
| 575 | 90 | 5.0 | 3.7 | ask | | 90B(Stealth) | 90 | 5.0 | 3.7 | ask |
|
Our factory trained technicians rebuild these pumps from what parts we can find. Since BOC acquired Stokes the stock of repair parts has been moved around. Contact us for availability.
90B Stealth Technical Data
| | Units | 90B |
|---|
| Displacement | cfm(m3/hr) | 90(153) |
| Pump speed | cfm(m3/hr) | 88(149) |
| Ultimate Vacuum with N2 purge | 10-3Torr | 10 |
| Typical N2 flow | slm | 20 |
| Typical Water flow | gpm(l/min) | 1(3.8) |
| Rated motor power |
| Blower | hp(kW) | N/A |
| Dry pump | hp(kW) | 5(3.7) |
| Inlet connection | | NW-50 |
| Exhaust connection | | NW-40 |
| Oil capacity |
| Blower | liter | N/A |
| Dry pump | liter | 0.5 |
| Weight | lb | 550 |
home index: A-M-Z e-mail PTB Sales toll free: 866-332-0500