The above listed configurations are only some of what we have available. E-mail support@ptbsales.com with the model number you need and we will reply back with the same or close match.
These Magnetron supplies are all passive front panel versions. The low voltage inputs are 180 to 229 VAC, 3 phase, 4 wire, 50 to 60 Hz; no neutral required.
No taps, mechanical or electrical, exist in the Pinnacle supply. The unit delivers full power over a 4:1 impedance range without the need for tap changes. You never need to open the unit or generate signals to control taps. Pinnacle Plus is a DC pulsed power supply.
The Pinnacle supply can be used as a power, current, or voltage source, depending on the method of output regulation selected. Since setpoint levels are stored in nonvolatile memory, you can use them to recover from input power interruptions and to ensure repeatability from run to run.
| Specifications | Pinnacle |
|---|---|
| Input Voltage | 200/208, 400 or 480 VAC (all ±10%) 3φ, 4 wire, 50 to 60 Hz, no neutral required |
| Efficiency | > 90% |
| Power Factor | 0.90 for loads > 1.2 kW |
| Output Voltage | Low Z, standard Z or high Z |
| Output Polarities | Floating default with positive and negative capability |
| Output Ripple Voltage | The component of output ripple voltage related to input line frequency is < 5% RMS |
| Output Power Repeatability | 0.1% from 10% to 100% of rated power (from run to run at a constant set point) |
| Remote Panel or Host Port | ±1% of full-rated output |
| User Port | 1% or ±0.2% of full-rated output, whichever is greater |
| Line Regulation | 1% for 10% line voltage change or ±2% frequency change |
| Load Regulation | ±1% for 4:1 load change within V-1 limits of tap range |
| Temperature Coefficient | < 0.005%/°C variation in the regulated output parameter over 20° to 40°C (68° to 104°F) ambient temperature range |
| Product Line (Overall) | Specification accuracy is Cpk < 1.5 |
| Analog Interface Options | 37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital 37-pin, 0 to 10 VDC analog, 0/15 VDC digital 37-pin, 0 to 5 VDC analog, 0/15 VDC digital |
| Serial Communication Options | RS-232, RS-422, RS-485 (selectable baud rates up to 57.6k) Profibus (selectable baud rates of 1.5 or 12 MB); AE Bus protocol DeviceNet option available |
| Output Power Connector | Three-terminal, multi-contact, pluggable connector (with shielded or plastic strain relief), UHF, military or ring lug |
| Input Power Connector | Five-terminal, DIN compression connector |
| Specifications | 5 kW, Single Output | 5 kW, Dual Output | 10 kW, Single Output |
|---|---|---|---|
| Max output power | 5 kW | 5 kW, independently controlled outputs | 10 kW |
| Voltage Range | 325 to 650 VDC; optional 325 to 800 VDC output (wide Z) | ||
| Max Current | 15.4 ADC | 15.4 ADC per output | 30.8 ADC |
| Input Power Connector | Five-terminal, DIN compression terminal block; maximum wire size: #6 AWG | ||
| Output Connector | Two-terminal, multi-contact, pluggable connector with strain relief or UHF connector | ||
| Frequency | 5 to 350 kHz, variable | ||
| Reverse Time | 0.4 to 5 ±s, variable; Optional 0.4 to 10 ±s range | ||
| Duty Cycle | Up to 45% reverse time, variable | ||
| Reverse Voltage | 10% of operating voltage (just prior to reversal) | ||
| Ignition Capability | 1,500 VDC max, 1,350 VDC typical | ||
| Regulation Modes | Power, voltage, or current | ||
| Repeatability | From run to run at constant set point: 0.1% from 10 to 100% of rated power | ||
| AC Line Voltage | 200/208 or 400 or 480 VAC | ||
| Current | 200/208 VAC: 17 A nominal per φ 400 VAC: 8.5 A nominal per φ 480 VAC: 7.5 A nominal per φ | 200/208 VAC: 35 A nominal per φ 400 VAC: 17 A nominal per φ 480 VAC: 15 A nominal per φ | |
| Regulatory Compliance | CE, NRTL on certain models | ||
| Ground Reference | Negative, positive, or floating output up to 1500 VDC with respect to ground or terminal to terminal | ||
| Analog Interface Options | 37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital 37-pin, 0 to 10 VDC or 0 to 5 VDC isolated analog, 0/15 VDC digital 37-pin, 0 to 10 VDC or 0 to 5 VDC non-isolated analog, 0/15 VDC digital | ||
| Serial Communication Options | RS-232, RS-422, RS-485 (selectable baud rates up to 57.6 k): AE Bus protocol; ASCII protocol (MDX and emulation) Profibus (selectable baud rates of 1.5 MB or 12 MB); AE Bus protocol DeviceNet± option available | ||
| Accessory | Remote, active monitor/control panel | ||
| Weight | 21.4 kg (47 lb) | 30 kg (66 lb) | |
| Max Recommended Output Cable Length | 10 m (32.8') RG393 or equivalent | ||
| Cooling Medium | Air | ||
| Input Power Connector | Five-terminal, DIN compression terminal block; maximum wire size: #6 AWG | ||
| Output Connector | Two-terminal, multi-contact, pluggable connector with strain relief or UHF connector | ||
$1,600 rebuilt Remote Active Panel. The Pinnacle supply can be controlled from an active front panel, a Pinnacle Remote Active Panel, an analog/digital connector (User port), or a serial communications (Host) port. The serial communications port, active front panel, and Pinnacle Remote Panel provide access to all operation parameters and control functions. The User port provides limited access to operating parameters and control functions.
The internal microprocessor checks for proper circuit operation while supervising all operating parameters. System diagnostics run when the unit is initially powered up. The most recent power settings and conditions (such as output production) are retained in non-volatile memory.
The displays on the passive panels as well as the control panels show power, current, or voltage levels. (The displays show levels for unit A and unit B if this is a dual unit). They also display information about output, setpoint, interlock, bus fault, over temperature, arcs, and error codes.
With the Pinnacle's arc-handling feature enabled, the hard-arc detection time is less than 1µs, and delivered are energy is less than 10 mJ for a kW inverter. (Depending on your unit's output configuration, the energy could be significantly less than 10 mJ).
Additionally, the arc-suppression feature enables you to implement preprogrammed arc-handling functions during your normal process cycle and your target conditioning cycle (TCC). In this mode the arc detect time and arc shutdown time are fixed by target type (metal or nonmetal). But you may also customize your arc shutdown and arc detect delay times by selecting the custom mode. Other parameters, including long arc count limit and voltage trip level, arc selectable through the Pinnacle Remote Active Panel or serial communications (Host) port.
The Pinnacle personality cards are designated in a two letter code that is part of the unit's SAP description. A typical description would look like this:
PNCL 6/6 400 PFP DDThe text in bold are the codes that describe the personality cards. The first letter describes the card in slot 2 and the second the card in slot 1. The type of card installed can also be determined by using the menus on an active front panel unit or by the codes flashed on the front of a passive panel at power up. The table below lists what the codes stand for:
| Letter | Description | Letter | Description |
|---|---|---|---|
| A | Profibus, Register Bases, 1 channel, isolated 1.5Mbaud rate, Certified | A | Profibus, Register Bases, 1 channel, isolated 1.5Mbaud rate, Certified |
| B | Profibus, Register Bases, 2 channel, isolated 1.5Mbaud rate, Certified | B | Profibus, Register Bases, 2 channel, isolated 1.5Mbaud rate, Certified |
| C | ASCII Serial Terminal Interface, non-isolated ENI emulator | C | Dual 15V User (Limited), 15 pin female, ENI emulator |
| D | AE Bus, non-isolated | D | Dual 15V User, non-isolated, 37 pin female |
| E | AE Bus, isolated | E | Single 15V User, non-isolated, 37 pin female MDX/MDXII compatible |
| F | Dual Output - Single 15V User, non-isolated, 37 pin, MDX compatible (req. 'F' in other slot & dual output unit | F | Dual Output - Single 15V User, non-isolated, 37 pin, MDX compatible (req. 'F' in other slot & dual output unit |
| G | Dual Output - Single 24V User, non-isolated, 37 pin (req. 'G' in other slot and dual output unit | G | Dual Output - Single 24V User, non-isolated, 37 pin (req. 'G' in other slot and dual output unit |
| H | Master/Slave, AE Bus, Isolated | H | Single 24V User, isolated, 37 pin male connector |
| I | MDX Host Protocol Translator, non-isolated | I | Dual 24V User, isolated, 37 pin male |
| J | DeviceNet with non-isolated Single 15V MDXL Emulator, 15 pin female | J | DeviceNet with non-isolated Single 15V MDXL Emulator, 15 pin female |
| K | Profibus, Command Based, 1 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified | K | Profibus, Command Based, 1 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified |
| L | Profibus, Command Based, 2 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified | L | Profibus, Command Based, 2 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified |
| M | ASCII Serial Terminal Interface, non-isolated CPI emulator | M | ASCII Serial Terminal Interface, non-isolated CPI emulator |
| N | Master/Slave, Profibus, isolated | N | Single 15V User, Isolated, 37 pin female |
| - | - | P | Pinnacle Plus 15V User, ENI Emulator, non- isolated, 25 pin female |
| X | Indicates 'Under Development' | X | Indicates 'Under Development' |
| Y | No Card Installed | Y | No Card Installed |
| Z | Custom | Z | Custom |
| Size H x W x D (inches) | |
|---|---|
| Power Supply | 5.2" x 19" x 25.2" - including connectors |
| Pinnacle Remote Active Panel | 3.5" x 19" x 4.2" |
| Weight (pounds) | |
| Power Supply | 6kW: 48 lbs., 12kW: 66 lbs. |
| Pinnacle Remote Active Panel | 13.9 lbs. |
We sell and provide repair service for most of the following models: Pinnacle I and Pinnacle II.
Call for a quote. 90 day warranty service on most Advanced Energy Pinnacle DC magnetron power supplies.