PTB Sales: 866-332-0500


Used Advanced Energy Pinnacle DC Magnetron

pinnacle

tested under load
ModelInputkWOutput VRebuilt
2338-018208V6 ask
2326-000400V6
6
400-800V
400-800V
$4,500
2362-011208V6400-800V$4,500
2363-005208V12 ask
2363-035208V10400-500Vask
2412-004   ask
2412-101   ask
2412-106208V10
6
325-650V
400-1,000V
ask
2412-107208V10
6
325-650V
400-1,000V
ask
2412-111208V10
6
325-650V
400-1,000V
ask
2412-115208V20650Vask
2412-116480V10
6
300-700V
400-1,000V
ask
2412-119208V10
6
325-650V
400-1,000V
ask

pinnacle
ModelInputkWOutput VRebuilt
2412-149208V20 ask
2412-199208V  ask
2412-213480V20400-1,000Vask
2412-218480V6400-1,000Vask
2412-223208V20 ask
2412-233480V20400-1,000Vask
2412-264480V20400-1,000Vask
2412-363400V20 ask

pinnacle
ModelInputkWOutput VRebuilt
2413-101   ask
2420-106208V20250-500Vask
2420-113208V20400-800Vask
2426-105208V12400-1,000Vask
2433-350208V101,600Vask
2435-100208V 650Vask
2603-001   ask

The above listed configurations are only some of what we have available. E-mail support@ptbsales.com with the model number you need and we will reply back with the same or close match.

These Magnetron supplies are all passive front panel versions. The low voltage inputs are 180 to 229 VAC, 3 phase, 4 wire, 50 to 60 Hz; no neutral required.

Output Impedance Range

No taps, mechanical or electrical, exist in the Pinnacle supply. The unit delivers full power over a 4:1 impedance range without the need for tap changes. You never need to open the unit or generate signals to control taps. Pinnacle Plus is a DC pulsed power supply.

Output Regulation

The Pinnacle supply can be used as a power, current, or voltage source, depending on the method of output regulation selected. Since setpoint levels are stored in nonvolatile memory, you can use them to recover from input power interruptions and to ensure repeatability from run to run.

SpecificationsPinnacle
Input Voltage200/208, 400 or 480 VAC (all ±10%)
3φ, 4 wire, 50 to 60 Hz, no neutral required
Efficiency> 90%
Power Factor0.90 for loads > 1.2 kW
Output VoltageLow Z, standard Z or high Z
Output PolaritiesFloating default with positive and negative capability
Output Ripple VoltageThe component of output ripple voltage related to input line frequency is < 5% RMS
Output Power Repeatability0.1% from 10% to 100% of rated power
(from run to run at a constant set point)
Remote Panel or Host Port±1% of full-rated output
User Port1% or ±0.2% of full-rated output, whichever is greater
Line Regulation1% for 10% line voltage change or ±2% frequency change
Load Regulation±1% for 4:1 load change within V-1 limits of tap range
Temperature Coefficient< 0.005%/°C variation in the regulated output parameter over 20° to 40°C (68° to 104°F) ambient temperature range
Product Line (Overall)Specification accuracy is Cpk < 1.5
Analog Interface Options37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital
37-pin, 0 to 10 VDC analog, 0/15 VDC digital
37-pin, 0 to 5 VDC analog, 0/15 VDC digital
Serial Communication OptionsRS-232, RS-422, RS-485 (selectable baud rates up to 57.6k)
Profibus (selectable baud rates of 1.5 or 12 MB); AE Bus protocol
DeviceNet option available
Output Power ConnectorThree-terminal, multi-contact, pluggable connector (with shielded or plastic strain relief), UHF, military or ring lug
Input Power ConnectorFive-terminal, DIN compression connector

Pinnacle Plus

Specifications5 kW, Single Output5 kW, Dual Output10 kW, Single Output
Max output power5 kW5 kW, independently controlled outputs10 kW
Voltage Range325 to 650 VDC; optional 325 to 800 VDC output (wide Z)
Max Current15.4 ADC15.4 ADC per output30.8 ADC
Input Power ConnectorFive-terminal, DIN compression terminal block; maximum wire size: #6 AWG
Output ConnectorTwo-terminal, multi-contact, pluggable connector with strain relief or UHF connector
Frequency5 to 350 kHz, variable
Reverse Time0.4 to 5 ±s, variable; Optional 0.4 to 10 ±s range
Duty CycleUp to 45% reverse time, variable
Reverse Voltage10% of operating voltage (just prior to reversal)
Ignition Capability1,500 VDC max, 1,350 VDC typical
Regulation ModesPower, voltage, or current
RepeatabilityFrom run to run at constant set point: 0.1% from 10 to 100% of rated power
AC Line Voltage200/208 or 400 or 480 VAC
Current200/208 VAC: 17 A nominal per φ
400 VAC: 8.5 A nominal per φ
480 VAC: 7.5 A nominal per φ
200/208 VAC: 35 A nominal per φ
400 VAC: 17 A nominal per φ
480 VAC: 15 A nominal per φ
Regulatory ComplianceCE, NRTL on certain models
Ground ReferenceNegative, positive, or floating output up to 1500 VDC with respect to ground or terminal to terminal
Analog Interface Options37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital
37-pin, 0 to 10 VDC or 0 to 5 VDC isolated analog, 0/15 VDC digital
37-pin, 0 to 10 VDC or 0 to 5 VDC non-isolated analog, 0/15 VDC digital
Serial Communication OptionsRS-232, RS-422, RS-485 (selectable baud rates up to 57.6 k): AE Bus protocol; ASCII protocol (MDX and emulation)
Profibus (selectable baud rates of 1.5 MB or 12 MB); AE Bus protocol
DeviceNet± option available
AccessoryRemote, active monitor/control panel
Weight21.4 kg (47 lb)30 kg (66 lb)
Max Recommended Output Cable Length10 m (32.8') RG393 or equivalent
Cooling MediumAir
Input Power ConnectorFive-terminal, DIN compression terminal block; maximum wire size: #6 AWG
Output ConnectorTwo-terminal, multi-contact, pluggable connector with strain relief or UHF connector
Interfaces
pinnacle-remote

$1,600 rebuilt Remote Active Panel. The Pinnacle supply can be controlled from an active front panel, a Pinnacle Remote Active Panel, an analog/digital connector (User port), or a serial communications (Host) port. The serial communications port, active front panel, and Pinnacle Remote Panel provide access to all operation parameters and control functions. The User port provides limited access to operating parameters and control functions.

Microprocessor Advantages

The internal microprocessor checks for proper circuit operation while supervising all operating parameters. System diagnostics run when the unit is initially powered up. The most recent power settings and conditions (such as output production) are retained in non-volatile memory.

Displays

The displays on the passive panels as well as the control panels show power, current, or voltage levels. (The displays show levels for unit A and unit B if this is a dual unit). They also display information about output, setpoint, interlock, bus fault, over temperature, arcs, and error codes.

Arc-Suppression Feature

With the Pinnacle's arc-handling feature enabled, the hard-arc detection time is less than 1µs, and delivered are energy is less than 10 mJ for a kW inverter. (Depending on your unit's output configuration, the energy could be significantly less than 10 mJ).

Additionally, the arc-suppression feature enables you to implement preprogrammed arc-handling functions during your normal process cycle and your target conditioning cycle (TCC). In this mode the arc detect time and arc shutdown time are fixed by target type (metal or nonmetal). But you may also customize your arc shutdown and arc detect delay times by selecting the custom mode. Other parameters, including long arc count limit and voltage trip level, arc selectable through the Pinnacle Remote Active Panel or serial communications (Host) port.

Pinnacle Personality Cards

The Pinnacle personality cards are designated in a two letter code that is part of the unit's SAP description. A typical description would look like this:

PNCL 6/6 400 PFP DD

The text in bold are the codes that describe the personality cards. The first letter describes the card in slot 2 and the second the card in slot 1. The type of card installed can also be determined by using the menus on an active front panel unit or by the codes flashed on the front of a passive panel at power up. The table below lists what the codes stand for:


LetterDescriptionLetterDescription
AProfibus, Register Bases, 1 channel, isolated 1.5Mbaud rate, CertifiedAProfibus, Register Bases, 1 channel, isolated 1.5Mbaud rate, Certified
BProfibus, Register Bases, 2 channel, isolated 1.5Mbaud rate, CertifiedBProfibus, Register Bases, 2 channel, isolated 1.5Mbaud rate, Certified
CASCII Serial Terminal Interface, non-isolated ENI emulatorCDual 15V User (Limited), 15 pin female, ENI emulator
DAE Bus, non-isolatedDDual 15V User, non-isolated, 37 pin female
EAE Bus, isolatedESingle 15V User, non-isolated, 37 pin female MDX/MDXII compatible
FDual Output - Single 15V User, non-isolated, 37 pin, MDX compatible (req. 'F' in other slot & dual output unitFDual Output - Single 15V User, non-isolated, 37 pin, MDX compatible (req. 'F' in other slot & dual output unit
GDual Output - Single 24V User, non-isolated, 37 pin (req. 'G' in other slot and dual output unitGDual Output - Single 24V User, non-isolated, 37 pin (req. 'G' in other slot and dual output unit
HMaster/Slave, AE Bus, IsolatedHSingle 24V User, isolated, 37 pin male connector
IMDX Host Protocol Translator, non-isolatedIDual 24V User, isolated, 37 pin male
JDeviceNet with non-isolated Single 15V MDXL Emulator, 15 pin femaleJDeviceNet with non-isolated Single 15V MDXL Emulator, 15 pin female
KProfibus, Command Based, 1 channel, isolated 12 Mbaud/1.5 Mbaud rate, certifiedKProfibus, Command Based, 1 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified
LProfibus, Command Based, 2 channel, isolated 12 Mbaud/1.5 Mbaud rate, certifiedLProfibus, Command Based, 2 channel, isolated 12 Mbaud/1.5 Mbaud rate, certified
MASCII Serial Terminal Interface, non-isolated CPI emulatorMASCII Serial Terminal Interface, non-isolated CPI emulator
NMaster/Slave, Profibus, isolatedNSingle 15V User, Isolated, 37 pin female
--PPinnacle Plus 15V User, ENI Emulator, non- isolated, 25 pin female
XIndicates 'Under Development'XIndicates 'Under Development'
YNo Card InstalledYNo Card Installed
ZCustomZCustom
Dimensions
Size H x W x D (inches)
Power Supply5.2" x 19" x 25.2" - including connectors
Pinnacle Remote Active Panel3.5" x 19" x 4.2"
Weight (pounds)
Power Supply6kW: 48 lbs., 12kW: 66 lbs.
Pinnacle Remote Active Panel13.9 lbs.

Advanced Energy Pinnacle DC Magnetron Service

We sell and provide repair service for most of the following models: Pinnacle I and Pinnacle II.

Call for a quote. 90 day warranty service on most Advanced Energy Pinnacle DC magnetron power supplies.

What you need, when you need it!


home     index: A-M-Z     e-mail      PTB Sales toll free: 866-332-0500