Specifications
|
OL400/602/19
|
OL6000/803/10
|
|
Input Voltage
|
187 to 229V AC single phase
|
Three phase 208V +10%, 48 to 62Hz
|
|
Input Current
|
<6A RMS
|
<27A per phase
|
|
Input Frequency
|
47 to 63Hz
|
-
|
|
Output Voltage
|
6kV/75mA
|
0 to 80kV DC/0 to 75mA
|
|
Calibration
|
Calibration between voltage demand, output voltage and voltage monitor +/-0.5% or 7.5v, whichever is greater
|
+/-0.5% or 100v, whichever is greater
|
|
Line Regulation
|
<3V for 10% line change
|
<16V change in output voltage for +10% change in input
|
|
Load Regulation
|
<3V for 0 to 100% change in current
|
<40V change in output voltage for a change in current between zero and rated current
|
|
Recovery Time
|
-
|
0.1 seconds to within 1% of set voltage
|
|
Ripple
|
<3V peak to peak
|
<150V peak to peak
|
|
Drift
|
-
|
<0.02%/hour, <0.05%/8 hours (after 1 hour warm up time)
|
|
Reliability
|
MTBF of 18,000 hours at 25°C
|
-
|
|
Efficiency
|
>80% at full power
|
-
|
|
Temp. Coefficient
|
<50ppm/°C (0 to +50°C)
|
<200ppm/°C
|
|
Operating Temp.
|
10°C to 40°C
|
10°C to +40°C
|
|
Storage Temp.
|
-20°C to +85°C
|
-20°C to +50°C
|
|
Humidity
|
95% maximum relative humidity
|
85% maximum relative humidity
|